Key specs

Users 1,000, codes 4 to 8 digits
Output Form C relay, 1 A at 30 VDC, up to 99,999 seconds
Power 12 to 24 VAC or VDC, 90 mA max at 12 VDC
Visitor codes Up to 50, one-time or 1 to 99 hours
Duress codes Up to 50
Tamper output N.C., 50 mA at 24 VDC
Size 4.63 x 2.88 x 1.5 in
Operating temperature -4 to 158 °F

Manuals and documents

Installation Manual

Programming Guide

Spec Sheet

Troubleshooting

The keypad beeps for one minute after power up. Enter programming with the master code followed by **.

Reset programming

  • In programming mode, enter 9999 # to restore all settings except the master code. The amber LED flashes fast while it works, then the keypad beeps twice.

Relay does not hold long enough

  • Set the output time in programming. It can run up to 99,999 seconds.

Common questions

No. The SK-1011-SDQ is an indoor keypad.

Program one of the 50 visitor codes for one-time use or for 1 to 99 hours.

Yes. Change the factory master code during setup and record the new one.