BD LOOPS SC 44-20 PREFORMED SAW-CUT LOOP 6'X16' w/ 20' LEAD

BD Loops ITEM: SC 44-20
BD LOOPS SC 44-20 PREFORMED SAW-CUT LOOP 6'X16' w/ 20' LEAD
BD LOOPS SC 44-20 PREFORMED SAW-CUT LOOP 6'X16' w/ 20' LEAD
BD LOOPS SC 44-20 PREFORMED SAW-CUT LOOP 6'X16' w/ 20' LEAD
BD LOOPS SC 44-20 PREFORMED SAW-CUT LOOP 6'X16' w/ 20' LEAD

BD LOOPS SC 44-20 PREFORMED SAW-CUT LOOP 6'X16' w/ 20' LEAD

BD Loops ITEM: SC 44-20
Regular price $142.50
/
  • Free shipping on most items over $200
  • We have 15+ years of industry experience
  • GSA, Net 30 and purchase orders available
Shipping calculated at checkout.

Description

**All BD Loops ship same day if ordered before 1pm cst **

Preformed Saw-Cut Inductance Loops

Used for installation in asphalt or concrete 3/16” saw-cut groove. The most common saw-cut installations involve cutting a 3/16” or wider slot into the concrete or asphalt, stuffing the loop wire into the saw-cut slot with the black side up, and sealing it with loop sealant. Our Saw-Cut Loops have an extra layer of protection: a durable outer jacket that shields and tightly binds the inner conductors.

Our BD Loops Preformed Saw-Cut Loops are built with solid 16AWG copper wire to create a tough, rigid product. Backer-rod is built into the wire! No need to use backer-rod if the loop is installed in a 3/16” saw-cut groove. Cuts don't need to be exact! Preformed Saw-Cut Loops can be made up to 4’ smaller. Be slightly conservative with your cuts, and BD Loops Preformed Saw-Cut Loops will fit every time.

  • Extra layer of protection—Thick and durable outer jacket protects both loop and lead-in.
  • Each loop is tested 3 ways before it leaves the factory.
  • Backer-rod is built into the wire! No need to use backer-rod if the loop is installed in a 3/16” saw-cut groove.
  • Lead-in wires are tightly bound in an protective outer
    jacket. Eliminating the need for twisting.
  • Both loop and lead-in fit into a 3/16” wide saw-cut groove. No more double cutting the lead-in run!
  • Loop fills up a larger percentage of the saw-cut groove, requires less loop sealant to seal the groove. (30-40% less sealant vs a 1/4” wide groove)
  • Cuts don’t need to be exact! Any BD Loop can be made up to 4’ smaller. Be slightly conservative with your cuts and BD Loops Preformed Saw-Cut Loops will fit every time.
  • Use the BD-LS flat 3/16″ sealant tip and seal the loop in just 1 pass. No more waiting around for the sealant to seep in and top off gaps. Make an attractive smooth and even seal.

See below for a comprehensive training and educational library from BD Loops

. Debunking Multi-Loop Configurations

. BD Loops Debunks Industry Myth – Loop
Wire Gauge

. BD Loops Debunks Industry Myth – Solid
Vs. Stranded Wire

. BD Loops Debunks Industry Myth – High
Voltage Lines And Loops.

. BD Loops Debunks Industry Myth –
Electrical Lines & Snow Melt Systems Near Loops

Top 10 Saw-Cut Loop Tips & Tricks

Replacing Old Loops? Read This!

. An Introduction To Inductance Loops
And Loop Phasing

. Loops And The Effect Of Parallel,
Series, And Phasing

. Loops: How To Insure Proper Placement
And Size

. Myths And Facts About Saw-Cut Loops

. Loops: Understanding And Preventing
Phantom Detections And Air Pockets

. The Importance Of Running The Lead-In
Through Conduit

. Training: Loops, Magnetism, And
Twisted Lead-Ins

. Choosing The Right Size Blade For
Saw-Cut Loops

. Saw-Cut Loop Tips And Tricks

Tests

. Loops And Power Lines

. Loops And Snow-Melt Systems

. Wire Gauge Comparison Test, Small & Large Loops.

. 16AWG Vs. 24AWG Loop Detection
Comparison

. Polyethylene Pipe Insulation Test

. Twisted Wire (In The Loop Itself) Test

. Shovel Test – Running Lead-In Through
Conduit

. Phasing Test

. TFFN / THHN Wire Test

. 1/8″ Groove Test

. Watch The Width

. Stand Off Distance

. Air Pocket Test

How To

. Direct Burial Preformed Loop
Installation Instructions
 

. Saw-Cut Preformed Loop Installation
Instructions
 

. Installing Loops Under Pavers

. Loop Size Chart

. How to Properly Meg a Loop

. How to Make a Preformed Saw-Cut Loop
Fit Every Time

. Loop Sealant Tips and Tricks

. Fully Seal the Saw-Cut Loop Yoke –
Installation Trick

. Modify a Saw-Cut Loop to a Direct
Burial Loop.

. Automatic Open (Free Exit) Loop
Formula

. Installing Loops in Asphalt

. BD Loops Sand Trick

. Saw-Cut Loop Tips and Tricks

. Repair Saw-Cut Loop Yoke –
Troubleshooting Trick

. Inductance Loop Warning Sign

All in stock orders typically ship the same business days or within 1-2 business days.  Cut off for same day shipping is 2:30PM Central Time.

LEADTIME

Items with lead times typically ship in 4-7 business days.

FREE SHIPPING POLICY

Orders with free shipping may have longer lead times due to those items being shipped the most economical way.  Free shipping on most orders over $195.00 does not include gate operators, loop sealant, and any extreme length or weight items

Our return policy lasts for only 30 days. If 30 days have gone by since your purchase, unfortunately we can’t offer you a refund. Some items such as Gate Operators or custom parts may not be returnable or carry a restocking fee if returned.

Read return policies

Protec Controls accepts purchase orders please contact us.

NET 30

We also support Net 30 terms on our website for easy ordering. Please fill out the form to the right with your company information and we will get your account setup to place Net 30 orders.

GOVERNMENT & GSA

Protec Controls accepts GSA SmartPay cards along with all major credit cards. For government quotes and purchase orders please email govsales@proteccontrols.com

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.