DoorKing 9100 Manuals & Support
Identify your model
The model and serial number are on the label inside the cover. Use the manual that matches your circuit board. The current manual covers board 4602-010 Rev AA or higher. The 2014 edition covers earlier boards.
Key specs
| Max gate | 1,000 lb / 30 ft |
|---|---|
| Motor | 1/2 HP, continuous duty |
| Power | 115 VAC single phase, 5.4 A |
| Speed | About 1 ft per second |
| Duty | 60 cycles per hour |
| Drive | Cog belt to #40 chain, 20 ft included |
| Limits | Magnetic, self-setting |
| Frame | G90 galvanized steel |
| UL 325 usage class | Class I, II, III and IV |
| Release | Fail-safe standard, fail-secure optional |
Manuals and documents
Installation Manual
-
9100 Installation and Owner's Manual
View PDF: 9100 Installation and Owner's Manual (opens in a new tab) -
9100 Manual, 2014 Edition
View PDF: 9100 Manual, 2014 Edition (opens in a new tab) -
9050 and 9100 Fail Secure Kit Instructions
View PDF: 9050 and 9100 Fail Secure Kit Instructions (opens in a new tab)
Quick Start
-
9100 Quick Start Guide
View PDF: 9100 Quick Start Guide (opens in a new tab)
Parts List
-
9100-080 Parts Drawing (115 VAC)
View PDF: 9100-080 Parts Drawing (115 VAC) (opens in a new tab)
Spec Sheet
-
9100 Spec Sheet
View PDF: 9100 Spec Sheet (opens in a new tab)
Brochure
-
DoorKing AC and DC Slide Operators Brochure
View PDF: DoorKing AC and DC Slide Operators Brochure (opens in a new tab)
Troubleshooting
Common questions
It will not run without at least one monitored Type B1 photo eye or Type B2 edge. Connect the device and turn on its UL 325 DIP switch input, then cycle power.
The limits are magnetic and set themselves. After power up, the first open command runs the gate through its cycles to find and remember the open and close positions.
The board has ports for DoorKing plug-in loop detectors, such as the 9410 single channel and 9409 dual channel.
A sounding alarm means a hard shutdown after an obstruction. Clear the obstruction and press the reset button on the operator.