EDI LMA-1250 Manuals & Support
Identify your model
The model is on the side label. LV models run on 10 to 40 VDC or 14 to 35 VAC. HV models run on 120 to 240 VAC. The LMA-1250S models are fail secure versions. The LMA-1250 replaces the discontinued LMA-100-LV, LMA-200-LV and LMA-1150-LV.
Key specs
| Channels | 1 loop, 2 relay outputs (5 A) |
|---|---|
| Power (LV) | 12 VDC, 24 VDC or 24 VAC (10 to 40 VDC or 14 to 35 VAC) |
| Connector | Rear 11-pin male (86CP11) |
| Output A | Limited or infinite presence |
| Output B | 250 ms pulse on entry or exit, duplicate of A, or fault output |
| Sensitivity | 10 levels; factory default 4 |
| Loop frequency | 4 settings by DIP switch |
| Timing | 2 second delay; 2, 5 or 10 second extension |
| Loop inductance | 20 to 2,500 µH |
| Fail mode | Fail-safe: Relay A closes common to NO on loop fault or power loss |
| Operating temperature | -30 to 165 °F |
Manuals and documents
Installation Manual
-
LMA-1250 Operating Instructions
View PDF: LMA-1250 Operating Instructions (opens in a new tab) -
Loop Installation Guide
View PDF: Loop Installation Guide (opens in a new tab)
Spec Sheet
-
LMA-1250 Data Sheet
View PDF: LMA-1250 Data Sheet (opens in a new tab)
Other documents
-
Loop Sizes and Loop Characteristics Chart
View PDF: Loop Sizes and Loop Characteristics Chart (opens in a new tab)
Troubleshooting
Common questions
F1 is an open loop, F2 is a shorted loop and F3 is a 25% inductance change. A normal display with a flashing fault LED means the fault happened before and has cleared.
Drive a typical car over the loop and watch the DEFLECTOMETER. A reading of 5 during the detect is the target. Use the front SENS buttons to raise or lower it.
The LMA-1250-LV is fail-safe: on a loop fault or power loss, Relay A closes common to NO. Order the LMA-1250S for fail secure.
Yes. It replaces the discontinued LMA-100-LV, LMA-200-LV and LMA-1150-LV and uses a standard 11-pin harness or socket.
Use direct-burial loop wire such as 16 AWG XLPE, not THHN. Twist the lead-in about 6 turns per foot from the loop to the detector, and seal saw cuts with loop sealant.