DoorKing 9024 Manuals & Support
Identify your model
The current 9024-380 uses circuit board 4100-018 Rev A or higher. The solar manual covers the 9024-081 with board 4100-010 Rev D or higher.
On a solar unit, several board switches must stay OFF. The solar manual lists them.
Key specs
| Class | UL 325 Class I, II, III and IV |
|---|---|
| Gate | Up to 40 ft and 1,000 lb |
| Speed | About 1 ft per second |
| 9024-380 power | 115 VAC at 1.8 A or 230 VAC at 0.9 A |
| 9024-380 backup | 40 cycles on the standard 7.2 Ah battery, 150 on optional 18 Ah batteries |
| 9024-081 power | 24 VDC at 8 A from the DKS solar kit |
| Board | 4100-018 (AC) or 4100-010 (solar) |
Manuals and documents
Installation Manual
-
9024-380 Slide Gate Operator Installation and Owner's Manual
View PDF: 9024-380 Slide Gate Operator Installation and Owner's Manual (opens in a new tab) -
9024-081 Solar Slide Gate Operator Installation and Owner's Manual
View PDF: 9024-081 Solar Slide Gate Operator Installation and Owner's Manual (opens in a new tab)
Parts List
-
9024-380 Parts Breakdown
View PDF: 9024-380 Parts Breakdown (opens in a new tab)
Troubleshooting
Common questions
No. Protec lists the 1601-154 heater for the AC-powered 9024 with 115 VAC input only.
The 9024-380 lists 40 cycles on the standard 7.2 Ah battery and 150 on the optional 18 Ah batteries.
Yes. The operator will not run until at least one monitored photo eye or edge is connected in each entrapment area. They are not included.