Identify your model
1050A-2: cast aluminum housing, 3.20 x 4.75 x 2.75 in, NEMA 4 (IP65). 1050A: steel housing version. A night light brightens when a code is entered. 1050X: earlier keypad with its own manual. 1050H: keypad with heater.
Key specs
| Codes | Up to 1,000 |
|---|---|
| Relays | Form C: relay 1 5 A, relay 2 1 A at 28 VDC |
| Power | 10 to 30 V AC or DC |
| Current draw | 100 mA active, 10 mA standby at 12 VDC |
| Rating | NEMA 4 (IP65) |
| Operating temperature | -20 to 140 °F, -40 °F with heater |
Manuals and documents
Installation Manual
-
1050A-2 Owners Manual, Installation and Programming
View PDF: 1050A-2 Owners Manual, Installation and Programming (opens in a new tab) -
1050A Owners Manual, Installation and Programming
View PDF: 1050A Owners Manual, Installation and Programming (opens in a new tab)
Programming Guide
-
1050X Installation and Programming Manual
View PDF: 1050X Installation and Programming Manual (opens in a new tab)
Spec Sheet
-
1050A-2 Data Sheet
View PDF: 1050A-2 Data Sheet (opens in a new tab) -
1050A Data Sheet
View PDF: 1050A Data Sheet (opens in a new tab) -
1050H Spec Sheet
View PDF: 1050H Spec Sheet (opens in a new tab)
Troubleshooting
Common questions
No. Codes are kept through a power failure.
Yes. Toggle mode latches the relay.
Yes. The optional 24 VAC heater extends operation to -40 °F.