HySecurity SwingSmart DC Swing Gate Operator Manuals & Support

HySecurity SwingSmart DC 20 / DCS 20

The HySecurity SwingSmart DC 20 is a pad mount swing gate operator for leaves up to 20 ft and 1,300 lb. It runs on a 24 VDC motor with continuous duty on AC power.

Battery backup gives up to 300 cycles with two 8 Ah batteries or 1,200 cycles with extended batteries. The DCS 20 is the solar model. SmartSync runs dual gates together.

Buy the SwingSmart DC 20 / DCS 20

Identify your model

The SwingSmart DC uses the Smart DC controller with a 32 character display. The patented taper clamp protects the gearbox from wind and gate strikes. The newer models are the SwingSmart CNX and SwingSmart 535.

Key specs

Max gate 1,300 lb at 12 ft; 800 lb at 16 ft; 600 lb at 20 ft
Open time 10 to 15 seconds, adjustable
Duty Continuous on AC; 100 cycles per day solar
Operating voltage 24 VDC
Input 115 VAC or 208 to 230 VAC
Battery backup Two 8 Ah: up to 300 cycles; two 50 Ah: up to 1,200 cycles
Accessory power 12 VDC and 24 VDC, 1 A each
Included EMX IRB-MON photo eye and two 8 Ah batteries
Operating temperature -13 to 158 °F

Manuals and documents

Installation Manual

Quick Start

Parts List

Spec Sheet

Troubleshooting

Smart Touch and Smart DC controllers show an Alert, Fault or Error on the display, chirp the buzzer and stop the gate. Every code is saved in the event log.

How to clear codes

  • ALERT: low priority. Give a new Open or Close command.
  • FAULT: press Stop or Reset.
  • ERROR: serious. Push Reset or cycle power, and call for service if it returns.

Common codes

  • ALERT 1, Forced Open: the gate was pushed off its limit. Check locks, alignment and the limit switch.
  • ALERT 8, Loop Shorted: megger the named loop to ground and check the lead-in.
  • ERROR 1, Direction Error: the opposite limit tripped. Check the limit switches and that their cables are in the right connectors.

Controller LED

  • The heartbeat LED on the controller flashes steadily during normal operation. If it is off, AC power is lost.

Common questions

UL 325 requires monitored external entrapment protection. Connect a monitored photo eye or edge and run the setup again.

Up to 300 cycles with the standard two 8 Ah batteries, or 1,200 cycles with extended batteries.

Yes. The SwingSmart DCS 20 is the solar model and needs at least 40 W of 24 VDC panels.