LiftMaster HDSL24UL Slide Gate Operator Manuals & Support

LiftMaster HDSL24UL

The LiftMaster HDSL24UL is a continuous-duty 24 VDC variable speed slide gate operator for gates up to 75 ft or 3,000 lb. Speed is adjustable from 1/2 to 1 ft per second.

It has a brushless motor with soft start and stop, battery backup, solar capability, 6 monitored safety inputs, 4 programmable auxiliary relays, Security+ 2.0 radio and myQ.

Buy the HDSL24UL

Identify your model

The HDSL24UL has a black powder-coated 1/4 in steel frame and a one-piece polyethylene cover.

Key specs

Max gate 3,000 lb / 75 ft
Speed 1/2 to 1 ft per second
Motor 24 VDC brushless, soft start and stop
Duty Continuous
Power 115 VAC or 230 VAC single phase, or solar
Gear reduction 40:1 direct drive
Monitored safety inputs 6
Auxiliary relays 4 programmable
Accessory power 24 VDC, 1 A
UL 325 usage class Class I, II, III and IV
Warranty 5 years commercial, 7 years residential
Operating temperature -4 to 140 °F; -40 °F with heater

Manuals and documents

Parts List

Spec Sheet

Brochure

Troubleshooting

To see codes, press and hold STOP, then CLOSE, then OPEN until "Er" shows on the diagnostic display. The display shows each saved code in order, starting with the most recent (01), up to 20 codes. Press STOP to exit.

Safety device codes

  • 60: the minimum monitored devices are not installed. A slide gate needs one external device in the close direction and one in the open direction.
  • 61 to 66: a photo eye or edge was held more than 3 minutes. Check alignment, wiring and obstructions.
  • 70 to 75: a photo eye or edge tripped and reversed the gate. If nothing was in the way, check alignment, inputs and wiring.

Travel and motor codes

  • 35: max run time exceeded. Check for an obstruction, then reprogram the limits.
  • 50: run distance error. Check the limit positions and that the switches work.
  • 91: force reversal. Check that the gate moves freely, then recheck the force setting.
  • 93: RPM or stall reversal. Check the operator wiring and the APE encoder assembly.

Power and battery codes

  • 31: board failure. Remove all power for 15 seconds, then reconnect. Replace the board if it comes back.
  • 40 or 41: battery overvoltage or overcurrent. Make sure the battery voltage matches the system and check the charge harness.
  • 42: no battery at boot up. Check connections. Replace batteries that read below 20 V on a 24 V system.
  • 53: brownout. Check the supply wiring.

Loop and dual gate codes

  • 43 to 45: exit, shadow or interrupt loop error on a LiftMaster plug-in detector. Check the loop for a short or open.
  • 54: lost wireless link to the second operator. Check its power, then relearn the second operator.

Common questions

It needs at least one monitored external device in the close direction and one in the open direction. Use LiftMaster monitored photo eyes or edges, such as the LMRRUL, LMTBUL or S505AL. Code 60 shows on the display until they are connected.

Press and hold STOP, then CLOSE, then OPEN until "Er" shows. Use OPEN and CLOSE to scroll through the last 20 codes, and press STOP to exit.

It has a Security+ 2.0 three-channel receiver for up to 50 remotes, such as the 811LM and 893MAX. Use the 811LMX or 813LMX for unlimited remotes.

Yes. Speed is adjustable from 1/2 to 1 ft per second.