LiftMaster LA400 Swing Gate Actuator Manuals & Support

LiftMaster LA400UL

The LiftMaster LA400 is a 24 VDC linear actuator for residential swing gates up to 16 ft or 850 lb. It opens 90° in about 17 seconds and is rated for 100 cycles per day.

Battery backup is standard, with up to 400 cycles or 97 days of standby. It has electronic limits, Security+ 2.0 radio, myQ, wireless dual-gate communication and solar capability.

Buy the LA400UL (3 options)

Identify your model

LA400PKGUL is the single gate kit. LA400DC is the primary arm only and LA400DCS the secondary arm. The 2012 LA400 manual covers earlier units before the UL control box.

Key specs

Max gate 850 lb / 16 ft per leaf
Open time About 17 seconds to 90°
Motor 24 VDC, soft start and stop
Duty 100 cycles per day
Power 115 VAC or 230 VAC single phase, or solar
Battery backup Two 7 Ah; up to 400 cycles or 97 days standby
Limits Electronic
Monitored safety inputs 3 on main board, 3 on optional expansion board
UL 325 usage class Class I, II, III and IV
Operating temperature -4 to 140 °F

Manuals and documents

Installation Manual

Wiring Diagram

Parts List

Spec Sheet

Brochure

Other documents

Troubleshooting

To see codes, press and hold STOP, then CLOSE, then OPEN until "Er" shows on the diagnostic display. The display shows each saved code in order, starting with the most recent (01), up to 20 codes. Press STOP to exit.

Safety device codes

  • 60: the minimum monitored devices are not installed. A swing gate needs at least one external device in the open or close direction.
  • 61 to 66: a photo eye or edge was held more than 3 minutes. Check alignment, wiring and obstructions.
  • 70 to 75: a photo eye or edge tripped and reversed the gate. If nothing was in the way, check alignment, inputs and wiring.

Travel and motor codes

  • 35: max run time exceeded. Check for an obstruction, then reprogram the limits.
  • 50: run distance error. Check the limit positions and that the switches work.
  • 91: force reversal. Check that the gate moves freely, then recheck the force setting.
  • 93: RPM or stall reversal. Check the operator wiring and the APE encoder assembly.

Power and battery codes

  • 31: board failure. Remove all power for 15 seconds, then reconnect. Replace the board if it comes back.
  • 40 or 41: battery overvoltage or overcurrent. Make sure the battery voltage matches the system and check the charge harness.
  • 42: no battery at boot up. Check connections. Replace batteries that read below 20 V on a 24 V system.
  • 53: brownout. Check the supply wiring.

Loop and dual gate codes

  • 43 to 45: exit, shadow or interrupt loop error on a LiftMaster plug-in detector. Check the loop for a short or open.
  • 54: lost wireless link to the second operator. Check its power, then relearn the second operator.

Common questions

It needs at least one monitored external device in the open or close direction. Use LiftMaster monitored photo eyes or edges, such as the LMRRUL, LMTBUL or S505AL. Code 60 shows on the display until they are connected.

Press and hold STOP, then CLOSE, then OPEN until "Er" shows. Use OPEN and CLOSE to scroll through the last 20 codes, and press STOP to exit.

Two 7 Ah batteries give up to 400 cycles or 97 days of standby after a power loss.

It has a Security+ 2.0 three-channel receiver for up to 50 remotes, such as the 811LM and 893MAX. Use the 811LMX or 813LMX for unlimited remotes.

Add the LA400DCS secondary arm. It wires to the primary control box.