Identify your model
The RSL12UL has a one-piece gray cover and drives #41 chain. It requires LiftMaster external entrapment protection in both directions before it will run.
Key specs
| Max gate | 800 lb / 25 ft |
|---|---|
| Speed | 10 in per second |
| Motor | 12 VDC, soft start and stop |
| Duty | 120 cycles per day |
| Power | 115 VAC single phase, or solar |
| Battery backup | Up to 114 cycles or 63 days standby |
| Gear reduction | 15:1 worm gear in oil bath |
| Chain | #41, 50 ft included |
| Accessory power | 12 VDC, 500 mA |
| UL 325 usage class | Class I, II, III and IV |
| Operating temperature | -4 to 140 °F; -40 °F with heater |
Manuals and documents
Installation Manual
-
RSL12UL Installation Manual
View PDF: RSL12UL Installation Manual (opens in a new tab)
Spec Sheet
-
RSL12UL Spec Sheet
View PDF: RSL12UL Spec Sheet (opens in a new tab) -
RSL12UL Product Data Sheet
View PDF: RSL12UL Product Data Sheet (opens in a new tab) -
LMWEKITU Wireless Edge Kit Data Sheet
View PDF: LMWEKITU Wireless Edge Kit Data Sheet (opens in a new tab) - RSL12UL Architectural Specification Download file: RSL12UL Architectural Specification (opens in a new tab)
Other documents
-
LiftMaster UL 325 Gate Safety Guide
View PDF: LiftMaster UL 325 Gate Safety Guide (opens in a new tab) -
LiftMaster Monitored Safety Devices Sheet
View PDF: LiftMaster Monitored Safety Devices Sheet (opens in a new tab)
Troubleshooting
Common questions
It needs at least one monitored external device in the close direction and one in the open direction. Use LiftMaster monitored photo eyes or edges, such as the LMRRUL, LMTBUL or S505AL. Code 60 shows on the display until they are connected.
Press and hold STOP, then CLOSE, then OPEN until "Er" shows. Use OPEN and CLOSE to scroll through the last 20 codes, and press STOP to exit.
Up to 114 cycles or 63 days of standby after a power loss.
It has a Security+ 2.0 three-channel receiver for up to 50 remotes, such as the 811LM and 893MAX. Use the 811LMX or 813LMX for unlimited remotes.
If someone pushes the gate off the closed limit, the operator powers up and returns it to closed.