Identify your model
The RSW12UL is a pad or post mount operator with a 2-piece cover. It requires a LiftMaster external entrapment protection device before it will run.
Key specs
| Max gate | 1,000 lb / 16 ft |
|---|---|
| Open time | About 15 seconds to 90° |
| Motor | 12 VDC, soft start and stop |
| Duty | 250 cycles per day |
| Power | 115 VAC single phase, or solar |
| Battery backup | Up to 147 cycles or 63 days standby |
| Gear reduction | 900:1 worm gear in oil bath |
| Accessory power | 12 VDC, 500 mA |
| UL 325 usage class | Class I, II, III and IV |
| Operating temperature | -4 to 140 °F; -40 °F with heater |
Manuals and documents
Installation Manual
-
RSW12UL Installation Manual
View PDF: RSW12UL Installation Manual (opens in a new tab) -
RSW12UL Cover Removal and Installation
View PDF: RSW12UL Cover Removal and Installation (opens in a new tab)
Wiring Diagram
-
RSW12UL Wiring Diagram
View PDF: RSW12UL Wiring Diagram (opens in a new tab)
Spec Sheet
-
RSW12UL Data Sheet
View PDF: RSW12UL Data Sheet (opens in a new tab) -
RSW12UL Spec Sheet
View PDF: RSW12UL Spec Sheet (opens in a new tab)
Troubleshooting
Common questions
It needs at least one monitored external device in the open or close direction. Use LiftMaster monitored photo eyes or edges, such as the LMRRUL, LMTBUL or S505AL. Code 60 shows on the display until they are connected.
Press and hold STOP, then CLOSE, then OPEN until "Er" shows. Use OPEN and CLOSE to scroll through the last 20 codes, and press STOP to exit.
Up to 147 cycles or 63 days of standby after a power loss.
It has a Security+ 2.0 three-channel receiver for up to 50 remotes, such as the 811LM and 893MAX. Use the 811LMX or 813LMX for unlimited remotes.