Seco-Larm SM-216Q Wide-Gap Surface Contact Manuals & Support

Seco-Larm SM-216Q

The Seco-Larm SM-216Q is a wide-gap surface-mount magnetic contact for alarm and access systems.

It has a 2-3/4 in gap for loose-fitting doors and windows, screw terminals and spacers. It comes in gray (SM-216Q/GY) or brown (SM-216Q/BR).

Buy the SM-216Q (3 options)

Identify your model

The SM-216Q is a long, flat surface contact, 3-15/16 in long, with screw terminals. /GY is gray and /BR is brown. The SM-217Q/W is the miniature white version with a 2 in gap.

Key specs

Mount Surface, screw
Gap 2-3/4 in
Loop Closed loop, N.O. reed
Magnet Alnico 5
Size 3-15/16 x 9/16 x 1/2 in each part
Colors Gray or brown
Contact rating 1.0 A at 10 VDC, 10 W max
Switch life 50 million cycles at 0.1 mA, 5 VDC
Operating temperature -15 to 160 °F

Manuals and documents

Installation Manual

Spec Sheet

Troubleshooting

Zone shows open with the door closed

  • Close the door and check the gap between switch and magnet. It must be inside the rated gap.
  • Line up the magnet with the switch. Use the included spacers if the parts sit at different heights.
  • Steel doors and frames weaken the magnet. Keep the gap smaller on steel or use a contact rated for steel doors.

Zone does not trip when the door opens

  • Set the panel zone for a closed loop (N.C.) device.
  • Check for a second magnet or other steel hardware near the switch.

False alarms

  • Check the wire connections and look for nicked leads.
  • A loose door that moves in the wind can open the loop. Use a wider gap contact on loose doors.

Common questions

Closed loop. The reed switch is closed when the magnet is next to it and opens when the door or window opens.

Install the switch and magnet on the protected side of the door or window so they cannot be reached from outside.

Loose doors, sliding doors and warehouse doors move too much for a 3/4 in gap contact. The 2-3/4 in gap stops false alarms from movement.