Part of the EZ Parts Finder: pick a part on the diagram or use the list below.
The diagram below maps replacement parts for the three phase Linear VS-GSLG slide gate operator. Select a part in any photo to read its part number. Everything is also listed below by assembly. The views show the main unit, the drive section with motor and brake, the control box, the limit box, the gearbox and the drive shaft with its pillow block bearings.
Identify your model
On a three phase VS-GSLG, the controller description reads 3-Phase along with the horsepower and voltage. The motors are listed as 208/230/460V three phase. Gate speed is set in Hz on the Hitachi drive, with a factory maximum of 95 Hz. Have the serial number ready when you order.
Related models: Linear VS-GSLG Single Phase
Operator and manuals
- Operator: Linear OSCO VS-GSLG-223 1/2 HP Variable Speed Slide Gate Operator
- VS-GSLG installation manual (PDF)
- VS-GSLG spec sheet (PDF)
- VS-GSLG electrical drawing (PDF)
Most ordered parts
- Tuerca de límite lineal 2200-030 (2200-030)
- Lineal 620-101293 Apex II (620-101293)
- Interruptor de límite lineal 2500-764 (2500-764)
- Placa de motor lineal OSCO 2500-1980 CA trifásica (2500-1980)
- FRENO Linear 2500-2397 CARA C 208/230/460 V CA (2500-2397)
- Lineal 2500-2315 MTR-L 1H 3P ODP R/CF 230/460 (2500-2315-UPS)
- Interruptor de límite lineal SPDT OMRON D2VW 2500-2347 (2500-2347)
- Placa de control lineal APEX OSCO 2500-2393 (2500-2393)
Parts list by assembly
Main
| Part number | Part |
|---|---|
| 2510-248 | Conjunto de soporte y botón de parada/reinicio Linear 2510-248 |
Drive Section
| Part number | Part |
|---|---|
| 2500-2315-UPS | Lineal 2500-2315 MTR-L 1H 3P ODP R/CF 230/460 |
| 2500-372 | Motor lineal 2500-372 MTR 2HP TE CF 3P 230/460 |
| 2500-2397 | FRENO Linear 2500-2397 CARA C 208/230/460 V CA |
| 2200-605 | Cadena Linear 2200-605 #40, 37 eslabones |
| 2200-817 | Arandela Belleville Linear 2200-817 |
| 2100-1650 | Placa lineal 2100-1650 TOR LIM VS/GSLG VGROOVE |
| 2300-390 | Disco de fricción lineal 2300-390 (par) |
| 2210-004 | Piñón lineal 2210-004, 40 A 48, con rodamiento |
| 2200-551 | Reductor lineal 2200-551 10:1 VS-GSLG GSL |
| 2200-654 | Cadena de eje de límite Linear 2200-654 (#48 / 30 eslabones) |
| 2100-910 | Manija de pestillo Linear 2100-910 |
| 2200-291 | Resorte de palanca de cambios y bloqueo Linear 2200-291 |
| 2120-132 | Conjunto de palanca de cambios Linear 2120-132 |
Control Box
| Part number | Part |
|---|---|
| 620-101293 | Lineal 620-101293 Apex II |
| 2500-2393 | Placa de control lineal APEX OSCO 2500-2393 |
| 2500-2084-HALF | Contactor lineal 2500-2084-half, 24 V CA, 4 polos, AB, medio |
| 2520-525 | Arnés de cableado Apex complejo Linear 2520-525 |
| 106604 | Lineal 106604: Antena local |
| 2510-530 | Variador de frecuencia lineal 2510-530 de 1/2 HP y 1 HP, 230 V, 3 polos |
| 2510-535 | Variador de frecuencia lineal 2510-535 de 1 HP y 1/2 HP, 460 V, 3 polos |
| 2500-2291 | Arrancador lineal 2500-2291, 30 A, 2 polos, 600 V |
| 2500-1980 | Placa de motor lineal OSCO 2500-1980 CA trifásica |
Limit Box
| Part number | Part |
|---|---|
| 2200-030 | Tuerca de límite lineal 2200-030 |
| 2100-057-UPS | Linear 2100-057-UPS EJE LÍMITE UPS ESTÁNDAR |
| 2500-2347 | Interruptor de límite lineal SPDT OMRON D2VW 2500-2347 |
| 2500-764 | Interruptor de límite lineal 2500-764 |
Gearbox
| Part number | Part |
|---|---|
| 2200-115 | Resorte de collar de desconexión Linear 2200-115 |
| 2110-131 | Conjunto de bloque de desconexión Linear 2110-131 |
| 2110-364 | Piñón lineal 2110-364, 40 A 24, con cojinete |
| 2400-017 | Arandela plana lineal 2400-017, 3/8" |
Drive Shaft
| Part number | Part |
|---|---|
| 2100-1737 | Placa de retención del bloque de almohada Linear 2100-1737 |
| 2100-1738-UPS | Eje de salida del UPS lineal 2100-1738 |
| 2200-042-PLT | Piñón lineal 2200-042-PLT 48-B-15, diámetro interior de 1" |
Common questions
What does the VS-GSLG need every six months?
Linear lists greasing the pillow block bearings, cleaning and oiling the main drive chain and sprockets with 40W oil, checking chain tension and making sure the gate moves freely by hand.
What gets checked every 12 months?
Check clutch tension and disc wear, limit switch adjustment and wear, tighten all nuts and bolts, and top up the gear reducer with #90/140 oil.
How is the gate speed set?
Speed is set in Hz on the Hitachi drive. The factory settings are a 95 Hz maximum and a 20 Hz minimum.