Identify your model
DSP-10-LV: 10 to 30 VDC or 10 to 28 VAC. DSP-10-117: 115 VAC version. Both are 2.36 x 1.75 x 4.09 in.
Key specs
| Channels | 1 loop, 2 relay outputs |
|---|---|
| Relays | NO and NC, 3 A |
| Power (LV) | 10 to 30 VDC or 10 to 28 VAC |
| Connector | 11-pin |
| Sensitivity | 10-position switch, 4 frequencies |
| Timing | Delay and extension |
Manuals and documents
Installation Manual
-
DSP-10 Manual
View PDF: DSP-10 Manual (opens in a new tab) -
Diablo Free Exit Probe Installation Instructions
View PDF: Diablo Free Exit Probe Installation Instructions (opens in a new tab)
Quick Start
-
DSP-10 Quick Reference Guide
View PDF: DSP-10 Quick Reference Guide (opens in a new tab)
Spec Sheet
-
DSP-10 Cut Sheet
View PDF: DSP-10 Cut Sheet (opens in a new tab)
Other documents
-
Loop Sizes and Loop Characteristics Chart
View PDF: Loop Sizes and Loop Characteristics Chart (opens in a new tab)
Troubleshooting
Common questions
Yes. The DSP-10 supports the Diablo Free Exit Probe.
Use the DSP-10-LV on low voltage operators and the DSP-10-117 on 115 VAC.
Use direct-burial loop wire such as 16 AWG XLPE, not THHN. Twist the lead-in about 6 turns per foot and seal saw cuts with loop sealant.