The DSP-21 is 2.36 x 1.75 x 4.09 in with an 11-pin connector. NO: normally open relays. 117: 115 VAC version.
Key specs
| Power (LV) | 10.5 to 35 VDC or 9 to 28 VAC |
|---|---|
| Outputs | NO relays, 1 A at 125 V |
| Connector | 11-pin |
| Loop inductance | 20 to 1,500 µH |
| Operating temperature | -35 to 165 °F |
Manuals and documents
Installation Manual
-
DSP-21 User Manual
View PDF: DSP-21 User Manual (opens in a new tab)
Spec Sheet
-
DSP-21 Cut Sheet
View PDF: DSP-21 Cut Sheet (opens in a new tab)
Troubleshooting
Common questions
Two loops of the same size, 2 to 4 ft apart, in the same lane.
Yes.
Use direct-burial loop wire such as 16 AWG XLPE, not THHN. Twist the lead-in about 6 turns per foot and seal saw cuts with loop sealant.