Diablo DSP-21 Directional Counting Detector Manuals & Support

Diablo DSP-21-NO-LV / DSP-21-117

The Diablo Controls DSP-21 is a two channel directional logic counting detector for a pair of loops. It counts vehicles by direction and handles tailgating, back-outs and parking moves.

Only the loop frequency needs setting. Count data is kept through a power loss.

Buy the DSP-21-NO-LV / DSP-21-117 (2 options)

Identify your model

The DSP-21 is 2.36 x 1.75 x 4.09 in with an 11-pin connector. NO: normally open relays. 117: 115 VAC version.

Key specs

Power (LV) 10.5 to 35 VDC or 9 to 28 VAC
Outputs NO relays, 1 A at 125 V
Connector 11-pin
Loop inductance 20 to 1,500 µH
Operating temperature -35 to 165 °F

Manuals and documents

Installation Manual

Spec Sheet

Troubleshooting

Gate does not open or reopen

  • Check the detect LED when a vehicle is on the loop.
  • Raise the sensitivity one step at a time.

Detector stays in detect

  • Check the loop and lead-in for a break or short to ground.
  • Reset the detector so it retunes.

Random detects

  • Set nearby detectors to different frequencies.
  • Check that the lead-in is twisted and the saw cut is sealed.

Common questions

Two loops of the same size, 2 to 4 ft apart, in the same lane.

Yes.

Use direct-burial loop wire such as 16 AWG XLPE, not THHN. Twist the lead-in about 6 turns per foot and seal saw cuts with loop sealant.