Identify your model
DSP-22-1: replaces DoorKing 9410. DSP-22-2: replaces DoorKing 9409 and 9405, channel 2 has a relay. DSP-22S-1: earlier DSP-22S model.
Key specs
| Power | 14 to 27 VDC |
|---|---|
| Draw | About 0.7 mA (22-1), 1.6 mA (22-2) |
| Output | Solid state 250 mA; relay on 22-2 channel 2 |
| Sensitivity | 4 levels plus boost |
| Fits | DoorKing detector ports |
Manuals and documents
Installation Manual
-
DSP-22-1 User Manual
View PDF: DSP-22-1 User Manual (opens in a new tab) -
DSP-22-2 Mini-Loop Installation Guide
View PDF: DSP-22-2 Mini-Loop Installation Guide (opens in a new tab) -
Diablo Free Exit Probe Installation Instructions
View PDF: Diablo Free Exit Probe Installation Instructions (opens in a new tab) -
DSP-22S Instructions, Earlier Edition
View PDF: DSP-22S Instructions, Earlier Edition (opens in a new tab)
Spec Sheet
-
DSP-22-1 Cut Sheet
View PDF: DSP-22-1 Cut Sheet (opens in a new tab) -
DSP-22-2 Cut Sheet
View PDF: DSP-22-2 Cut Sheet (opens in a new tab) -
DSP-22S Cut Sheet, Earlier Edition
View PDF: DSP-22S Cut Sheet, Earlier Edition (opens in a new tab)
Other documents
-
Loop Sizes and Loop Characteristics Chart
View PDF: Loop Sizes and Loop Characteristics Chart (opens in a new tab)
Troubleshooting
Common questions
The 22-1 replaces the 9410. The 22-2 replaces the 9409 and 9405.
Yes, in pulse mode.
Not with a probe or in fail-secure. Use presence and a loop.