EDI LMA-1400 DEFLECTOMETER Loop Detector Manuals & Support

EDI LMA-1400

This model is discontinued. Manuals and replacement parts for existing units are listed below.

The EDI LMA-1400 is a single channel loop detector with a DEFLECTOMETER display and two programmable outputs. It is fail-safe.

It flags open loops, shorted loops and large inductance changes. It is discontinued.

Buy the LMA-1400

Identify your model

-M: relay, 10-pin male Molex. -MS: solid state, fail-secure. -F and -FS: female Molex. -B and -BS: terminal block.

Key specs

Power 12 to 24 VDC or 24 VAC
Outputs 2 relay or solid state
Display DEFLECTOMETER
Temperature -30 to 165 F

Manuals and documents

Installation Manual

Spec Sheet

Other documents

Troubleshooting

Detector does not see vehicles

  • Check loop resistance and megger the loop to ground.
  • Check that the lead-in is twisted and the splice is sealed.

Random detects

  • Seal the slot so the wires cannot move.
  • Keep loops at least 3 ft from other loops and moving metal.

Common questions

EDI names no direct replacement. For female Molex ports use the LMA-1800.

Match the connector and output to the operator.

How much the loop changes, to help set sensitivity.