EMX ULT-PLG Manuals & Support
Identify your model
The ULT-PLG is a small board with a 10-pin female connector, a rotary sensitivity switch and an ULTRAMETER display. It is for operators with a 10-pin plug-in detector port. For an 11-pin socket, see the MVP D-TEK or ULT-MVP-2.
Key specs
| Channels | 1 loop |
|---|---|
| Power | 12 to 24 VDC, 15 mA |
| Connector | 10-pin female plug-in |
| Outputs | Solid-state (open collector): presence, Output B, Output B inverted |
| Sensitivity | 10 levels, 0 to 9, with ULTRAMETER display |
| Loop frequency | 4 settings |
| Loop inductance | 20 to 2,000 µH |
| Operating temperature | -40 to 180 °F |
Manuals and documents
Installation Manual
-
ULT-PLG Instruction Manual
View PDF: ULT-PLG Instruction Manual (opens in a new tab) -
Loop Wire Installation
View PDF: Loop Wire Installation (opens in a new tab) -
Lite Preformed Loop Instructions
View PDF: Lite Preformed Loop Instructions (opens in a new tab)
Spec Sheet
-
ULT-PLG Spec Sheet
View PDF: ULT-PLG Spec Sheet (opens in a new tab)
Other documents
-
EMX Loop Size Chart
View PDF: EMX Loop Size Chart (opens in a new tab) -
TSTL Test Loop Instructions
View PDF: TSTL Test Loop Instructions (opens in a new tab)
Troubleshooting
Common questions
It fits operators with a 10-pin plug-in loop detector port. Check the operator manual for the port and pinout before you order.
No. Outputs are solid-state open collector outputs that the operator board reads directly.
Most sites run 3 or 4. Drive a vehicle onto the loop and set the switch to the number the ULTRAMETER shows.
Use direct-burial loop wire such as 16 AWG XLPE, not THHN. Twist the lead-in about 6 turns per foot from the loop to the detector, and seal saw cuts with loop sealant.