LiftMaster SL595 Slide Gate Operator Manuals & Support

LiftMaster SL595UL

The LiftMaster SL595 is an industrial AC slide gate operator with 1, 1-1/2 or 2 HP motors. It moves the gate at 12 in per second and handles gates up to 90 ft or 2,500 lb on the 2 HP model.

It has a 20:1 oil-bath worm gear, #50 chain, mechanical limits, a 7-gauge frame, Security+ 2.0 radio and myQ. Single and three phase models are available.

Buy the SL595UL (4 options)

Identify your model

The model code gives HP and power: SL595101UL is 1 HP single phase, SL595151UL 1-1/2 HP single phase, SL595103UL 1 HP three phase and SL595203UL 2 HP three phase.

Key specs

Max gate 1 HP: 70 ft / 1,700 lb; 1-1/2 HP: 80 ft / 2,100 lb; 2 HP: 90 ft / 2,500 lb
Speed 12 in per second
Duty 25 cycles per hour
Power 115/208/230 VAC single phase; 208/230/460 VAC three phase; 575 VAC three phase
Gear reduction 20:1 worm gear in oil bath
Chain #50 nickel-plated, 25 ft included
Limits Mechanical
Accessory power 24 VDC, 500 mA
UL 325 usage class Class I, II, III and IV
Operating temperature -4 to 140 °F; -40 °F with heater

Manuals and documents

Installation Manual

Spec Sheet

Brochure

Other documents

Troubleshooting

To see codes, press and hold STOP, then CLOSE, then OPEN until "Er" shows on the diagnostic display. The display shows each saved code in order, starting with the most recent (01), up to 20 codes. Press STOP to exit.

Safety device codes

  • 60: the minimum monitored devices are not installed. A slide gate needs one external device in the close direction and one in the open direction.
  • 61 to 66: a photo eye or edge was held more than 3 minutes. Check alignment, wiring and obstructions.
  • 70 to 75: a photo eye or edge tripped and reversed the gate. If nothing was in the way, check alignment, inputs and wiring.

Travel and motor codes

  • 35: max run time exceeded. Check for an obstruction, then reprogram the limits.
  • 50: run distance error. Check the limit positions and that the switches work.
  • 91: force reversal. Check that the gate moves freely, then recheck the force setting.
  • 93: RPM or stall reversal. Check the operator wiring and the APE encoder assembly.
  • 95: AC motor did not start. Check the motor, the relay board and the start capacitor connections.

Power and board codes

  • 31: board failure. Remove all power for 15 seconds, then reconnect. Replace the board if it comes back.
  • 47 or 59: power board fault or missing power board. Check the harness and the power board.
  • 53, 55 or 56: brownout, AC overvoltage or AC undervoltage. Check supply voltage and wire gauge to the operator.
  • 57 or 58: limit switch stuck or wrong switch. Check the limit switches and motor wiring.

Loop and dual gate codes

  • 43 to 45: exit, shadow or interrupt loop error on a LiftMaster plug-in detector. Check the loop for a short or open.
  • 54: lost wireless link to the second operator. Check its power, then relearn the second operator.

Common questions

It needs at least one monitored external device in the close direction and one in the open direction. Use LiftMaster monitored photo eyes or edges, such as the LMRRUL, LMTBUL or S505AL. Code 60 shows on the display until they are connected.

Press and hold STOP, then CLOSE, then OPEN until "Er" shows. Use OPEN and CLOSE to scroll through the last 20 codes, and press STOP to exit.

It has a Security+ 2.0 three-channel receiver for up to 50 remotes, such as the 811LM and 893MAX. Use the 811LMX or 813LMX for unlimited remotes.

Check the label: 101 is 1 HP single phase, 151 is 1-1/2 HP single phase, 103 is 1 HP three phase and 203 is 2 HP three phase.