Identify your model
The model code gives HP and power: SL595101UL is 1 HP single phase, SL595151UL 1-1/2 HP single phase, SL595103UL 1 HP three phase and SL595203UL 2 HP three phase.
Key specs
| Max gate | 1 HP: 70 ft / 1,700 lb; 1-1/2 HP: 80 ft / 2,100 lb; 2 HP: 90 ft / 2,500 lb |
|---|---|
| Speed | 12 in per second |
| Duty | 25 cycles per hour |
| Power | 115/208/230 VAC single phase; 208/230/460 VAC three phase; 575 VAC three phase |
| Gear reduction | 20:1 worm gear in oil bath |
| Chain | #50 nickel-plated, 25 ft included |
| Limits | Mechanical |
| Accessory power | 24 VDC, 500 mA |
| UL 325 usage class | Class I, II, III and IV |
| Operating temperature | -4 to 140 °F; -40 °F with heater |
Manuals and documents
Installation Manual
-
SL595UL Installation Manual
View PDF: SL595UL Installation Manual (opens in a new tab)
Spec Sheet
-
SL595 Spec Sheet
View PDF: SL595 Spec Sheet (opens in a new tab) - SL595UL Architectural Specification Download file: SL595UL Architectural Specification (opens in a new tab)
Brochure
-
SL595UL Product Guide
View PDF: SL595UL Product Guide (opens in a new tab)
Other documents
-
SL595 Dimension Drawing
View PDF: SL595 Dimension Drawing (opens in a new tab)
Troubleshooting
Common questions
It needs at least one monitored external device in the close direction and one in the open direction. Use LiftMaster monitored photo eyes or edges, such as the LMRRUL, LMTBUL or S505AL. Code 60 shows on the display until they are connected.
Press and hold STOP, then CLOSE, then OPEN until "Er" shows. Use OPEN and CLOSE to scroll through the last 20 codes, and press STOP to exit.
It has a Security+ 2.0 three-channel receiver for up to 50 remotes, such as the 811LM and 893MAX. Use the 811LMX or 813LMX for unlimited remotes.
Check the label: 101 is 1 HP single phase, 151 is 1-1/2 HP single phase, 103 is 1 HP three phase and 203 is 2 HP three phase.