Seco-Larm SD-998C Surface-Mount Electric Rim Strikes Manuals & Support

Seco-Larm SD-998C-D3Q / SD-998C-BD3A

The Seco-Larm SD-998C strikes are surface-mount electric rim strikes for rim exit devices with a Pullman latch. They mount on the frame with no cutting.

They run on 12 or 24 VDC, are field selectable fail-safe or fail-secure and are UL 294 and UL 1034 listed. The SD-998C-D3Q takes a 3/4 in latch throw; the black SD-998C-BD3A takes 1/2 in.

Buy the SD-998C-D3Q / SD-998C-BD3A (2 options)

Identify your model

SD-998C-D3Q: 3/4 in housing, stainless. SD-998C-BD3A: 1/2 in housing, black. The older SD-998C-NUAQ was replaced by the SD-998C-D3AQ. The SD-998SMB aluminum bracket mounts the strike on the face of the frame where it cannot go on the stop. The latch-monitor version is the SD-998CM-SD3A.

Key specs

Latch throw D3Q: 3/4 in; BD3A: 1/2 in
Operating voltage 12 or 24 VDC, non-polarized
Current draw 540 mA at 12 VDC, 270 mA at 24 VDC
Mode Fail-safe or fail-secure, field selectable
Static strength 1,500 lb
Dynamic strength 70 ft-lb
Endurance 250,000 cycles
Listings UL 294, UL 1034
Use Indoor

Manuals and documents

Installation Manual

Spec Sheet

Troubleshooting

Strike does not release

  • Check the wiring connector on the strike and confirm 12 or 24 VDC at the strike.
  • Measure voltage at the strike while it is energized. Low voltage means the wire is too small or the power supply is too small.
  • Check the keypad, exit button or controller that triggers the strike.

Door does not open when the strike releases

  • Check that the latch moves freely. Move the strike or add shims so the latch is not bound.

Strike buzzes

  • Run the strike on a DC power supply, not AC.

Common questions

No. It surface mounts on metal or wood frames.

Rim exit devices with a Pullman latch, up to 3/4 in throw for the D3Q or 1/2 in for the BD3A.

No. Use 12 or 24 VDC. AC power makes it buzz.