Viking K-2 Manuals & Support
Identify your model
The model is on the label inside the cover. Units built from 2013 on use the VFlex control board with an LCD display. Check the logo color on the board: black logo boards are 2013 to 2016, green logo boards are 2016 to 2018 and orange logo boards are 2018 and later.
First generation units (2009 to 2012) use an older control board and some different parts. Use the first generation manual below for those units.
Key specs
| Max gate | 700 lb / 30 ft |
|---|---|
| UL 325 usage class | Class I (residential) |
| Motor | DC direct drive, rated by Viking as equal to 1/3 HP AC |
| Duty cycle | 100% |
| Operating voltage | 24 VDC |
| Main power | 115 VAC or 240 VAC single phase, 1.5 A / 1.0 A |
| Alternative power | 24 VAC/VDC (60 VA) or solar |
| Accessory power | 24 VDC, 750 mA |
| Motor current, typical | 5.0 A |
| Battery backup | Two 12 V, 7 Ah batteries included |
| Operating temperature | -20 to 160 °F |
| Gate speed | About 12 in per second |
Manuals and documents
Installation Manual
-
K-2 Installation Manual
View PDF: K-2 Installation Manual (opens in a new tab) -
K-2 Manual, 1st Generation
View PDF: K-2 Manual, 1st Generation (opens in a new tab)
Parts List
-
K-2 Parts Diagram
Download file: K-2 Parts Diagram (opens in a new tab) -
K-2 Parts Diagram, 1st Generation
Download file: K-2 Parts Diagram, 1st Generation (opens in a new tab)
Spec Sheet
-
K-2 Spec Sheet
View PDF: K-2 Spec Sheet (opens in a new tab)
Troubleshooting
Common questions
A slide gate needs at least two monitored 10K sensors: one on UL and one on Re-Open, or two on UL, one for each direction of travel. Wire them, then run the UL LEARN process from the Diagnose button.
Lift the access door on the front of the cover and press the Manual Release switch to RELEASE. Push the switch to ENGAGE to run again.
It uses two 12 V, 7 Ah batteries (Viking DUBA12 or Yuasa NP7-12). A full charge reads about 26 VDC across both batteries. Check terminals for corrosion when you service the operator.
The alarm sounds after a second obstruction in a row. Remove the obstruction and press the Alarm Reset button on the operator.
Check the logo color on the VFlex board. Black logo boards are 2013 to 2016, green logo boards are 2016 to 2018 and orange logo boards are 2018 and later. Order the board that matches your logo color or the current orange logo board.