BEA Single Door Access Control Packages Manuals & Support

BEA 10ACP12 / 10ACP12F / 10ACP6 / 10ACP6F

BEA 10ACP packages hold the parts for one request to exit door: a UL listed maglock, a request to exit sensor, a push to exit button, a BR3-X logic module and a power supply.

Pick the maglock size and the sensor type. The wiring diagram for each package shows every connection.

Buy the 10ACP12 / 10ACP12F / 10ACP6 / 10ACP6F (4 options)

Identify your model

10ACP12: 1,200 lb maglock, R2E-100 active infrared sensor. 10ACP6: 600 lb, R2E-100. 10ACP12F: 1,200 lb, FLY passive infrared sensor. 10ACP6F: 600 lb, FLY.

Key specs

Maglock 600 or 1,200 lb UL 294
Sensor R2E-100 or FLY
Logic BR3-X
Power supply 10PS12-24
Doors 1

Manuals and documents

Wiring Diagram

Troubleshooting

Lock does not hold

  • Check the supply voltage at the lock.
  • Check that the armature plate meets the magnet flat.
  • Clean the magnet and armature faces.

Door does not release

  • Check that the release device cuts power to the lock.
  • Check the relock delay setting.

Common questions

No. Maglock brackets and filler plates are separate.

R2E-100 is active infrared. FLY is passive infrared.

One.