HySecurity HydraSwing Hydraulic Swing Gate Operator Manuals & Support

HySecurity HydraSwing 40 / 40F / 80F / 150

The HySecurity HydraSwing is a low profile hydraulic swing gate operator for large gates and high wind sites. Models handle leaves up to 40 ft and up to 15,000 lb.

It is rated for continuous duty with soft start and stop, uses the Smart Touch controller and is ETL listed to UL 325 for Class I to IV.

Buy the HydraSwing 40 / 40F / 80F / 150 (6 options)

Identify your model

F models are fast. Twin models run two leaves. The HydraSwing 80F and 150 are the heavy duty models with a stainless steel cover. MX3121-03: 15 m (49 ft) encoder cable, discontinued. HySecurity added MX3121-05 at 6 m (20 ft) and MX3121-02 at 10 m (33 ft) in 2022.

Key specs

Max gate 40: 4,000 lb / 24 ft; 40F: 4,000 lb / 16 ft; 80F: 8,000 lb / 16 ft; 150: 15,000 lb / 30 ft
Open time 40: 15 to 20 s; 40F: 10 to 15 s; 80F and 150: 15 to 30 s
Horsepower 2 HP
Drive Hydraulic
Duty Continuous
Power 208 or 230 VAC single phase; 208, 230, 380 or 460 VAC three phase
Controller Smart Touch, 70+ settings
UL 325 usage class Class I, II, III and IV
Operating temperature -40 to 158 °F

Manuals and documents

Installation Manual

Programming Guide

Wiring Diagram

Parts List

Spec Sheet

Service Bulletin

Other documents

Troubleshooting

Smart Touch and Smart DC controllers show an Alert, Fault or Error on the display, chirp the buzzer and stop the gate. Every code is saved in the event log.

How to clear codes

  • ALERT: low priority. Give a new Open or Close command.
  • FAULT: press Stop or Reset.
  • ERROR: serious. Push Reset or cycle power, and call for service if it returns.

Common codes

  • ALERT 1, Forced Open: the gate was pushed off its limit. Check locks, alignment and the limit switch.
  • ALERT 8, Loop Shorted: megger the named loop to ground and check the lead-in.
  • ERROR 1, Direction Error: the opposite limit tripped. Check the limit switches and that their cables are in the right connectors.

Controller LED

  • The heartbeat LED on the controller flashes steadily during normal operation. If it is off, AC power is lost.

Common questions

The 40 handles 4,000 lb up to 24 ft, the 80F 8,000 lb up to 16 ft and the 150 up to 15,000 lb and 30 ft per leaf.

Yes, with the optional AC Power Supply with HyInverter AC.

UL 325 requires monitored external entrapment protection. Connect a monitored photo eye or edge and run the setup again.