Linear SWR Residential Swing Gate Operator Manuals & Support

Linear SWR

The Linear SWR is a residential crank arm swing gate operator with a 1/2 HP PSC motor. It handles gates up to 15 ft and 500 lb, opens in 11 to 14 seconds and is rated for 150 cycles per day.

It runs on 115 or 230 VAC and uses the APeX controller with a built-in radio receiver, plug-in loop detector capability and dual gate link.

Buy the SWR (2 options)

Identify your model

The SWR is a pad mount crank arm swing operator with a black polyethylene cover and an exterior reset button. The SWR, SWC and SWD share one installation guide. See also the SWR, SWC and SWD.

Key specs

Max gate 500 lb / 15 ft
Motor 1/2 HP PSC
Power SWR-211: 115 VAC; SWR-221: 230 VAC
Open time 11 to 14 seconds
Duty 150 cycles per day
Drive Right-angle gear reducer, 1 in output shaft
Mount Pad mount; post mount optional
Approvals UL 325 and UL 991

Manuals and documents

Installation Manual

Wiring Diagram

Spec Sheet

Other documents

Troubleshooting

The APeX controller shows status on its 2-digit display and LEDs. Press STOP to clear most errors once the cause is fixed.

Error codes

  • En 00: two safety reversals in a row. Clear the obstruction and press STOP.
  • En 01 or En 02: maximum run timer ran out while opening or closing. Check for a broken chain or belt, a slipping pulley or a timer set too low.
  • En 03: dual gate COMM LINK failure. Check the 3-wire shielded cable between operators.
  • En 04: battery dropped below 21.6 VDC after AC power loss. Restore AC power and let the batteries charge.
  • En 07: low AC voltage at the controller. Restore normal supply voltage.
  • En 10: EEPROM problem. Try a reset.
  • En 11: DC motor check failed. Reprogram the motor type.

Operator fails to start

  • The motor thermal overload may have tripped after many cycles. Let it cool and it resets.
  • Check power at the breaker panel.

Gate stops part way with no obstruction

  • Current sensing set too low. Make sure the gate moves freely, then raise the setting.
  • An accessory on the obstruction input triggered. Disconnect devices one at a time to find it.

Motor runs but gate does not move

  • Check the torque limiter for slipping and tighten it if needed.
  • Check for a broken chain or worn belts and loose set screws or keys.

Common questions

Yes. The APeX controller has an integral MegaCode receiver that learns up to 40 Linear MegaCode transmitters.

The operator saw two safety reversals in a row and locked out. Clear the obstruction, then press STOP to reset.

The SWR is residential, 150 cycles per day for gates up to 15 ft and 500 lb. The SWC is commercial, continuous duty for gates up to 19 ft and 1,000 lb.