Miller Edge ME120 Sensing Edge Manuals & Support

Miller Edge ME120

The Miller Edge ME120 is a slide-in sensing edge for gates and motorized doors. It fits 1-1/2 in gate surfaces and mounts vertically or horizontally in an aluminum or PVC channel.

It is a UL 325 recognized component, comes in black or yellow, and is offered monitored (10K, 8.2K or diode) or as a 2-wire normally open edge.

Buy the ME120 (7 options)

Identify your model

The ME120 has a two-sided profile. 10K monitored versions are marked with a blue band. Combo kits pair the edge with a Miller Edge wireless transmitter and receiver.

Key specs

Profile For 1-1/2 in gate surfaces
Max length Electric 100 ft
Activation force 6 to 10 lbf nominal
Electrical 24 VAC/DC, 1/2 A, normally open
Monitoring 10K, 8.2K, diode, or 2-wire non-monitored
Lead 2 ft SJTO 18 AWG
Approvals UL 325 recognized component

Manuals and documents

Installation Manual

Spec Sheet

Troubleshooting

Gate or door does not stop on contact

  • Read the edge with an ohmmeter. A 10K edge reads about 10K ohms at rest and near zero when pressed. A 2-wire NO edge reads open at rest.
  • Check the lead wire and outlet for damage.
  • Make sure the edge type matches the operator input.

Edge slides in the channel

  • Drill a 1/8 in hole in the channel 2 in from the end and add a #10 pan head screw to hold the edge.

Common questions

Most gate operators built after January 2016 need a monitored edge. The 10K version is the most common. Check the operator manual.

Disconnect it and read it with an ohmmeter. A 10K edge reads about 10,000 ohms at rest and drops near zero when pressed. A 2-wire normally open edge reads open at rest and near zero when pressed.

Yes. With the ME120-C5 channel it protects the entrapment zone along the driveway under a swing gate.