The Reno A&E RAD-1 is a single channel plug-in loop detector with two solid state outputs. It plugs into a 10-pin Molex detector port.

Output A is presence. Output B is set for fault, presence, pulse on entry or pulse on exit. It tunes itself to the loop.

Buy the RAD-1-PL

Identify your model

RAD-1-PL: 2.30 x 2.5 x 0.80 in with rear 10-pin Molex (09-48-1104). Fits Elite SL3000 and CSW200, All-O-Matic DC, Viking and other 10-pin ports.

Key specs

Power 10 to 30 VDC or 14 to 26 VAC
Outputs 2 solid state, 100 mA at 30 VDC
Sensitivity 4 levels
Loop range 20 to 2100 uH
Temperature -30 to 165 F

Manuals and documents

Installation Manual

Spec Sheet

Troubleshooting

Detector does not see vehicles

  • Check loop resistance and megger the loop to ground.
  • Check that the lead-in is twisted and the splice is sealed.

Random detects

  • Seal the slot so the wires cannot move.
  • Keep loops at least 3 ft from other loops and moving metal.

Common questions

Operators with a 10-pin Molex detector port. See the spec sheet list.

No. Use an 11-pin relay detector for contacts.

The EDI LMA-1800.