SOS - Siren Operated Sensors SOS Siren Operated Sensors Manuals & Support

SOS - Siren Operated Sensors SOS 12 / SOS

The SOS Siren Operated Sensor opens a gate when an emergency vehicle holds its siren on yelp. Responders do not stop for a code or key.

Sensitivity is set so passing vehicles on the road do not open the gate. The output wires to the operator open input.

Buy the SOS 12 / SOS (2 options)

Identify your model

SOS 12: NEMA 4 enclosure, dial sensitivity, hold for one vehicle, 15 minutes or until reset, test CD and sign included. SOS: compact sensor with momentary or 15 minute hold.

Key specs

SOS 12 power 9 to 30 VDC or 9 to 16 VAC
SOS 12 draw 0.1 mA listening, 25 mA triggered
SOS power 12 to 24 VAC or VDC
Trigger Siren yelp, about 3 s
Enclosure NEMA 4 (SOS 12)

Manuals and documents

Installation Manual

Spec Sheet

Troubleshooting

Gate does not open on siren

  • Raise the sensitivity one step.
  • Test with the test CD.
  • Check the output wiring to the operator open input.

Gate opens from road traffic

  • Lower the sensitivity.
  • Aim the microphone away from the road.

Common questions

Play the siren yelp test CD near the sensor.

No. It responds to the siren.

Check local fire department rules for emergency gate access.