Tomar STROBESWITCH 1790 Emergency Gate Access Manuals & Support

Tomar 1790-1014 / 1790M-2 / 2795

The Tomar STROBESWITCH reads the coded light from emergency vehicle emitters and opens the gate. It ignores flashlights, light bars and flashing signs.

Detectors connect to a 1790M-2 power module, which holds the gate open for a set time.

Buy the 1790-1014 / 1790M-2 / 2795 (5 options)

Identify your model

1790-1014: detector only. 1790M-2: power module, up to 3 detectors. 1790-1014-S&M2: one detector with module. 2795-2 and 2795-3: two and three detector assemblies. 1760-14: tester.

Key specs

Range About 200 ft
View 10 x 90 degrees
Module power 12 to 24 VAC/VDC
Hold time 0 to 30 min or latch
Emitters Tomar and GTT Opticom

Manuals and documents

Installation Manual

Spec Sheet

Troubleshooting

Gate does not open for the emitter

  • Check the detector LED with the 1760-14 tester.
  • Aim the detector down the approach.
  • Check the module relay wiring to the operator open input.

Common questions

Up to 3.

Tomar and GTT Opticom emitters.

With the Tomar 1760-14 tester.