BD Loops BD EL 14 to EL 32 Direct Burial Loops Manuals & Support

BD Loops EL 14 to EL 32

BD Loops EL 14 to EL 32 are preformed direct burial vehicle loops from 3 x 4 ft up to 4 x 12 or 6 x 10 ft. The loop wire runs inside a PVC jacket.

Each has a 60 or 100 ft lead-in with a flex yoke and 1/2 in coupler for conduit.

Buy the EL 14 to EL 32 (9 options)

Identify your model

EL 14: 3 x 4 ft. EL 16: 3 x 5 or 4 x 4 ft. EL 20: 3 x 7 or 4 x 6 ft. EL 24: 4 x 8 or 6 x 6 ft. EL 28: 4 x 10 or 6 x 8 ft. EL 32: 4 x 12 or 6 x 10 ft. EL 14, 16 and 20 come with 60 ft of lead-in. The others come with 60 or 100 ft.

Key specs

Sizes 3 x 4 ft to 6 x 10 ft (14 to 32 ft perimeter)
Lead-in 60 or 100 ft
Jacket PVC
Conduit fitting Flex yoke, 1/2 in coupler
Use Under new pours, pavers or base

Manuals and documents

Installation Manual

Spec Sheet

Other documents

Troubleshooting

Detector does not see vehicles

  • Check loop resistance and megger the loop to ground.
  • Check that the lead-in is twisted and the splice is sealed.

Random detects

  • Seal the slot so the wires cannot move.
  • Keep loops at least 3 ft from other loops and moving metal.

Common questions

Before the pour or pavers go down. Set it on the base and tie it so it stays flat.

A 24 ft perimeter loop, 4 x 8 or 6 x 6 ft, with a 100 ft lead-in.

Lead-in length. EL has 60 or 100 ft, RL has 40 ft.