BD Loops BD SC 24 to SC 32 Saw-Cut Loops Manuals & Support

BD Loops SC 24 / SC 28 / SC 32

BD Loops SC 24 to SC 32 are preformed saw-cut vehicle loops from 4 x 8 or 6 x 6 ft up to 4 x 12 or 6 x 10 ft. Each comes with a 20, 50 or 100 ft factory lead-in.

The wire is 16 AWG in a jacket rated 600 V and 167 °F. It fits a 3/16 in slot.

Buy the SC 24 / SC 28 / SC 32 (8 options)

Identify your model

The SC code reads perimeter, then lead-in. SC 24: 4 x 8 or 6 x 6 ft. SC 28: 4 x 10 or 6 x 8 ft. SC 32: 4 x 12 or 6 x 10 ft. The last number is the lead-in in feet.

Key specs

Sizes 4 x 8 ft to 6 x 10 ft (24 to 32 ft perimeter)
Lead-in 20, 50 or 100 ft
Wire 16 AWG
Slot 3/16 in wide, 1-1/4 to 1-1/2 in deep
Rating 600 V, 167 °F

Manuals and documents

Installation Manual

Spec Sheet

Other documents

Troubleshooting

Detector does not see vehicles

  • Check loop resistance and megger the loop to ground.
  • Check that the lead-in is twisted and the splice is sealed.

Random detects

  • Seal the slot so the wires cannot move.
  • Keep loops at least 3 ft from other loops and moving metal.

Common questions

A 32 ft perimeter loop, 4 x 12 or 6 x 10 ft, with a 100 ft lead-in.

A 3/16 in slot, 1-1/4 to 1-1/2 in deep. Cut 45 degree corners or core the corners.

Use BD Loop Shield or another loop sealant. See the BD sealant chart.

Measure from the loop to the detector and add slack. Do not splice if the lead-in reaches.