EMX PR Lite Preformed Loops Manuals & Support

EMX PR-26 / PR-46 / PR-48 / PR-410 / PR-610 / PR-812

EMX PR Lite loops are preformed inductive loops in flexible TPE tubing with built-in lightning protection. They connect to any vehicle loop detector.

They go in a saw cut in existing pavement, under an asphalt overlay, or tied in place before a concrete pour. The lead-in is twisted and jacketed.

Buy the PR-26 / PR-46 / PR-48 / PR-410 / PR-610 / PR-812 (12 options)

Identify your model

The number gives the size in feet: PR-46 is 4 x 6 ft and PR-812 is 8 x 12 ft. No suffix: 50 ft lead. -100: 100 ft lead.

Key specs

Sizes 2x6, 4x6, 4x8, 4x10, 6x10 and 8x12 ft
Lead-in 50 or 100 ft, twisted, jacketed
Tubing TPE, 0.26 in OD
Saw cut 1 in deep, 45 degree corners
Temperature -4 to 194 F

Manuals and documents

Installation Manual

Spec Sheet

Other documents

Troubleshooting

Loop fault on the detector

  • Check loop resistance and megger the loop to ground before you pour or pave.
  • Check that no lead-in was cut or crushed during the pour.

Poor detection

  • Check that the loop is the right size for the lane.
  • Check that the lead-in is not run next to power wires.

Common questions

Yes. EMX calls for a 1 in deep cut with 45 degree corner cuts.

Yes. The loop does not detect on its own.

Pick 50 or 100 ft to reach the detector without a splice.