Identify your model
The ULT-DIN clips onto DIN rail and measures 80 x 23 x 84 mm. It is part of the ULTRALOOP family with the plug-in ULT-PLG and ULT-MVP.
Key specs
| Power | 12 to 24 VDC |
|---|---|
| Mounting | DIN rail, 80 x 23 x 84 mm |
| Sensitivity | 10 settings with ULTRAMETER display |
| Outputs | Presence relay plus second relay |
| Second relay | Loop fault, pulse on entry or exit, or DETECT-ON-STOP |
| Features | Automatic sensitivity boost, delay, fail-safe or fail-secure |
Manuals and documents
Installation Manual
-
ULT-DIN Instruction Manual
View PDF: ULT-DIN Instruction Manual (opens in a new tab) -
Loop Wire Installation
View PDF: Loop Wire Installation (opens in a new tab) -
Lite Preformed Loop Instructions
View PDF: Lite Preformed Loop Instructions (opens in a new tab)
Spec Sheet
-
ULT-DIN Spec Sheet
View PDF: ULT-DIN Spec Sheet (opens in a new tab) -
Lite Preformed Loop Spec Sheet
View PDF: Lite Preformed Loop Spec Sheet (opens in a new tab)
Other documents
-
ULTRALOOP Detect-On-Stop Application Note
View PDF: ULTRALOOP Detect-On-Stop Application Note (opens in a new tab) -
TSTL Test Loop Instructions
View PDF: TSTL Test Loop Instructions (opens in a new tab) -
EMX Loop Size Chart
View PDF: EMX Loop Size Chart (opens in a new tab)
Troubleshooting
Common questions
12 to 24 VDC.
Use direct-burial loop wire such as 16 AWG XLPE, not THHN. Twist the lead-in about 6 turns per foot from the loop to the detector, and seal saw cuts with loop sealant.
It only calls when a vehicle comes to a full stop on the loop, so cross traffic in tight spaces is ignored.