The EMX ULT-DIN is an ULTRALOOP vehicle loop detector in a small DIN rail module. It runs on 12 to 24 VDC.

It has an ULTRAMETER sensitivity display, crosstalk and interference display, 10 sensitivity settings and DETECT-ON-STOP. A second relay can be set for loop fault, pulse on entry or exit, or DETECT-ON-STOP.

Buy the ULT-DIN

Identify your model

The ULT-DIN clips onto DIN rail and measures 80 x 23 x 84 mm. It is part of the ULTRALOOP family with the plug-in ULT-PLG and ULT-MVP.

Key specs

Power 12 to 24 VDC
Mounting DIN rail, 80 x 23 x 84 mm
Sensitivity 10 settings with ULTRAMETER display
Outputs Presence relay plus second relay
Second relay Loop fault, pulse on entry or exit, or DETECT-ON-STOP
Features Automatic sensitivity boost, delay, fail-safe or fail-secure

Manuals and documents

Installation Manual

Spec Sheet

Other documents

Troubleshooting

Green LED off

  • No power. Check for 12 to 24 VDC.

Green LED fast flash

  • Loop shorted or open. Loop should read 0.5 to 5 ohms and steady. Check terminals and press FREQUENCY COUNT / RESET.

Green LED two fast flashes

  • A past loop fault. Check the loop and connections, then press FREQUENCY COUNT / RESET.

Red LED stuck on

  • Megger the loop to ground (over 100 megaohms).
  • Check crimps, splices and terminals.
  • Watch the ULTRAMETER for residual shift and press FREQUENCY COUNT / RESET.

Common questions

12 to 24 VDC.

Use direct-burial loop wire such as 16 AWG XLPE, not THHN. Twist the lead-in about 6 turns per foot from the loop to the detector, and seal saw cuts with loop sealant.

It only calls when a vehicle comes to a full stop on the loop, so cross traffic in tight spaces is ignored.